Pregnant woman scale scheme
Date:2020/10/22 Source:Shenzhen Weishengkang Technology Co., Ltd

Brief introduction of pregnant woman scale
Power on mode: gravity power on or power on
Display accuracy: 1500 degree
Calibration mode: 2-point calibration: 2kg, 5kg
Memory function: three groups of memory
Power consumption: without backlight, the working current is less than 4mA; the average shutdown current is less than 3ua
Power off time: power off 10 ± 2 seconds after no action, power off 10 ± 2 seconds after weighing lock meeting
Low voltage display "Lo" for 3S and then shut down;
After the weight is stable, it will shut down automatically within 10 ± 2 seconds
Low voltage detection: one point or two points detection
Key types: touch, touch, toggle
Working voltage: 3.0V
Important parameters of pregnant woman scale scheme
Unit: G, ML, LB, oz
Range: 5kg
Zero range: 10g
Weighing capacity: 2.0kg
Zero range: 2kg